Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | Yes |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
This PEM Fuel Cell test bench includes the following functions to analyse the fuel cell performance.
1. Real-time software interface, which can display the voltage and current output status of the fuel cell stack in real time, and can store and analyse the data in real time.
2. Precise control and measurement of fuel flow parameters, used to analyse the influence of hydrogen and air parameters on fuel cell stack power generation and find the best fuel cell stack control parameters. 3. precise control and measurement of air flow/temperature/humidity/pressure parameters, used to analyse fuel cell stack power generation.
3. Precise control and measurement of air flow/temperature/humidity/pressure parameters, which is used to analyse the influence of air parameter changes during fuel cell stack power generation and find the best fuel cell stack control parameter.
4. Circulating water module, supplying appropriate deionised water to the fuel cell to study the performance changes of the fuel cell under different temperatures.
TR X1800 Fuel Cell Test Equipment Specifications
|
|
Battery-loaded Equipment
|
|
Maximum Wattage
|
0-1800W |
Electronic Load Type
|
Resistor Type
|
Current Range
|
0~150A
|
Current Resolution
|
1mA
|
Current Accuracy
|
0.05%+0.1%F.S
|
Voltage Range
|
0~60V
|
Voltage Resolution
|
0.1mV
|
Voltage Accuracy
|
0.05%+0.1%F.S
|
Data Capture Speed
|
0.1s
|
Interface Format
|
LAN
|
Constant Potentiometer (Optional)
|
|
Current Range
|
0~100A
|
Parameter
|
500 mA, 5 A, 20 A, 50 A
|
Current Accuracy
|
±0.2%
|
Voltage Measurement Accuracy
|
≤ 0.1 % of range + 0.1 % of reading
|
Current Measurement Accuracy
|
≤ 0.1 % of range + 0.5 % of reading
|
Voltage Range
|
±5V
|
Test Frequency Range
|
1mHz-100kHz
|
The Following Conditions Required Before Installing The Equipment
|
|
Pure Water: Water Pressure
|
400 kPa.g,
|
Water Flow Rate
|
>20cc/mi>20cc/min
|
Pure Water Impedance Value
|
>=15M Ω
|
Nitrogen: Purity
|
>99.995%,>10.5NLPM@6~7kg/cm2
|
Air Compression
|
Purity level <=ISO8573-1Class1No water, no oil,>5NLPM@6~7kg/cm2
|
Client need to prepare all the gas, water and electricity pipelines and power supply lines of the plant before you can connect with the equipment preparation.
|